Spedizione rapida per la sostituzione completa del sensore di sicurezza

Safety Controller QCA

Safety Controller QCA

Cataloghi ProdottiController
MarchioDADISICK
ModelloController QCA
Mains Input:AC100V~230V±15% 50/60 Hz : DC24V±10%
Overall Power Consumption:≤5W
Input Voltage:WC220V or WC110V
Output Voltage:DC12V or DC24V
Output Current:≤200mA
Output:One normally open, one normally closed (standard
Response Time:<20ms
Certificate:ISO, CE, UL ,FCC, TUV
Aggiornare il Tempo2024/11/24
Informazioni Dettagliati
Safety controller product model
Controler
QCA
Certificate
ISO, CE, UL, FCC, TUV
Features
Mains input
AC 100 V~230 V ± 15% 50/60 Hz; DC 24 V ± 10%
Overall power consumption
≤5 W
Input voltage
WC 220 V  or WC 110 V
Output voltage
DC 12 V or DC 24 V
Output current
≤200 mA
Output form
One normally open, one normally closed (standard configuration)
Output contact capacity
5 A,AC 250 V / DC 30 V (Resistive load)
Response time
<20 ms
Lifetime of relay
≥1 million times (Electrical Life)
Mechanical data
Case material
Plastics
Install
Installation of guide rail slot
Mode of connection
Connect the plug
Maximum wire size
0.5m²
Environmental characteristics
Work environment temperature
-10°C ~ 55°C
Storage temperature
-40℃ ~ 70℃
Work ambient humidity
35%RH ~ 85%RH
Storage ambient humidity
35%RH ~ 95%RH
Level of protection
IP20
Boundary dimension
115 × 90 × 73 mm
THE INSTALLATION OF THE CONTROLLER

1. Installation tools

 

(1) Electric drill, drill bit (specification:Φ4.3, (5.2,6.8), tap (specification: M5,M6,M8).Cross and slotted screwdriver, hexagon wrench (specification: 6#.8#), adjustable wrench (specification: 22"),                  Needle nose pliers.etc

(2) The installation of the controller bracket requires a 5.2 drill and M6 tap

(3) The installation ofthe photoelectric support base requires a 6.8 drill bit and an M8 tap

(4) The fixing hole of the crimping buckle of the transmission line needs a 4.3 drill bit and an M5 tap

 

2. Installation of built-in controller

         Connect the controller directly to the 35mm electrical rail. lnstalled in the electrical cabinet of the machine.

Safety Controller
Controller Dimensional Drawing
Controller dimension
Controller wiring diagram
Controller Wiring Diagram
Controller QCA-3D.STEP
valutare
  • Caricamento in corso...
Prodotti correlati
    Mandaci per favore il messaggio d’acquisto.
    *Email
    Nome
    *Titolo
    *Contenuto
    Carica
    • Supporta solo .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, massimo 20M